Square Butte (transmission line)
http://dbpedia.org/resource/Square_Butte_(transmission_line) an entity of type: Place
Square Butte is the designation of a high-voltage direct current transmission line in the United States between the Milton R. Young Power Plant near Center, North Dakota at 47°4′18″N 101°11′45″W / 47.07167°N 101.19583°W and the Arrowhead converter station near Adolph (a neighborhood of the city of Hermantown near the city of Duluth, Minnesota) at 46°46′25″N 92°17′39″W / 46.77361°N 92.29417°W. It was built by Minnkota Power Cooperative and and went in service in 1977. In 2009, an agreement was executed between the two companies whereby Minnkota gets the rights to all the power currently transmitted over the line (and which is now carried over a newly built 345kV transmission line) while Minnesota Power takes full ownership of the line to transmit power from new sources in the Center ar
rdf:langString
rdf:langString
Square Butte (transmission line)
xsd:float
47.0716667175293
xsd:float
-101.1958312988281
xsd:integer
1658182
xsd:integer
1072762927
xsd:string
47.071666666666665 -101.19583333333334
rdf:langString
Square Butte is the designation of a high-voltage direct current transmission line in the United States between the Milton R. Young Power Plant near Center, North Dakota at 47°4′18″N 101°11′45″W / 47.07167°N 101.19583°W and the Arrowhead converter station near Adolph (a neighborhood of the city of Hermantown near the city of Duluth, Minnesota) at 46°46′25″N 92°17′39″W / 46.77361°N 92.29417°W. It was built by Minnkota Power Cooperative and and went in service in 1977. In 2009, an agreement was executed between the two companies whereby Minnkota gets the rights to all the power currently transmitted over the line (and which is now carried over a newly built 345kV transmission line) while Minnesota Power takes full ownership of the line to transmit power from new sources in the Center area. Square Butte can transfer up to 500 megawatts at a symmetrical voltage of 250 kV. The whole line is implemented as overhead line on steel lattice towers, with a single conductor per HVDC pole (i.e. a total of two for the HDVC bipole), with a length of 449 miles (749 kilometers). The line crosses the Missouri River north of Price between 47°5′30″N 100°56′28″W / 47.09167°N 100.94111°W and 47°5′30″N 100°55′54″W / 47.09167°N 100.93167°W in a 718 metres long span. As is the case for modern HVDC-systems thyristor static inverters are used.
xsd:nonNegativeInteger
3772
<Geometry>
POINT(-101.19583129883 47.071666717529)