Mahoney tables

http://dbpedia.org/resource/Mahoney_tables

Les tables de Mahoney sont une série de tables de référence d'architecture utilisées comme guide pour obtenir des bâtiments au design adapté aux . Elles tirent leur nom de l'architecte , qui les a créées avec et . Elles ont été publiées pour la première fois en 1969 par le département des affaires économiques et sociales des Nations unies. Il y a six tables. Quatre sont utilisées pour entrer les données climatiques : Les deux autres tables indiquent les recommandations architecturales à respecter telles que l'orientation du bâtiment, la position, la dimension ou l'exposition des ouvertures. rdf:langString
The Mahoney tables are a set of reference tables used in architecture, used as a guide to climate-appropriate design. They are named after architect Carl Mahoney, who worked on them together with John Martin Evans, and Otto Königsberger. They were first published in 1971 by the United Nations Department of Economic and Social Affairs. The concept developed by Mahoney (1968) in Nigeria provided the basis of the (from sites such as http://www.wunderground.com/global/AG.html, 2006). — John Martin Evans, The Comfort Triangles rdf:langString
rdf:langString Tables de Mahoney
rdf:langString Mahoney tables
xsd:integer 3743670
xsd:integer 1059871735
rdf:langString Les tables de Mahoney sont une série de tables de référence d'architecture utilisées comme guide pour obtenir des bâtiments au design adapté aux . Elles tirent leur nom de l'architecte , qui les a créées avec et . Elles ont été publiées pour la première fois en 1969 par le département des affaires économiques et sociales des Nations unies. Les tables utilisent des données climatiques faciles à obtenir et des calculs simples aboutissent aux lignes directrices. Ainsi elles ne donnent que des indications qualitatives mais évitent la complexité de modélisations telles que la simulation thermique dynamique. Il y a six tables. Quatre sont utilisées pour entrer les données climatiques : 1. * Températures : moyennes mensuelles des températures maximales et minimales ; 2. * Humidité, précipitations et vent ; 3. * Comparaison des limites de confort et du climat ; 4. * Indicateurs : par combinaison des données des tables précédentes, classification de l'humidité ou de l'aridité pour chaque mois. Les deux autres tables indiquent les recommandations architecturales à respecter telles que l'orientation du bâtiment, la position, la dimension ou l'exposition des ouvertures.
rdf:langString The Mahoney tables are a set of reference tables used in architecture, used as a guide to climate-appropriate design. They are named after architect Carl Mahoney, who worked on them together with John Martin Evans, and Otto Königsberger. They were first published in 1971 by the United Nations Department of Economic and Social Affairs. The concept developed by Mahoney (1968) in Nigeria provided the basis of the Mahoney Tables, later developed by Koenigsberger, Mahoney and Evans (1970),published by the United Nations in English, French and Spanish, with large sectionsincluded in the widely distributed publication by Koenigsberger et al. (1978).The Mahoney Tables (Evans, 1999; Evans, 2001) proposed a climate analysis sequencethat starts with the basic and widely available monthly climatic data of temperature,humidity and rainfall, such as that found in HMSO (1958) and Pearce and Smith (1990),or data published by national meteorological services, for example SMN (1995).Today, the data for most major cities can be downloaded directly from the Internet (from sites such as http://www.wunderground.com/global/AG.html, 2006). — John Martin Evans, The Comfort Triangles The tables use readily available climate data and simple calculations to give design guidelines, in a manner similar to a spreadsheet, as opposed to detailed thermal analysis or simulation. There are six tables; four are used for entering climatic data, for comparison with the requirements for thermal comfort; and two for reading off appropriate design criteria. A rough outline of the table usage is: 1. * Air Temperatures. The max, min, and mean temperatures for each month are entered into this table. 2. * Humidity, Precipitation, and Wind. The max, min, and mean figures for each month are entered into this table, and the conditions for each month classified into a humidity group. 3. * Comparison of Comfort Conditions and Climate. The desired max/min temperatures are entered, and compared to the climatic values from table 1. A note is made if the conditions create heat stress or cold stress (i.e. the building will be too hot or cold). 4. * Indicators (of humid or arid conditions). Rules are provided for combining the stress (table 3) and humidity groups (table 2) to check a box classifying the humidity and aridity for each month. For each of six possible indicators, the number of months where that indicator was checked are added up, giving a yearly total. 5. * Schematic Design Recommendations. The yearly totals in table 4 correspond to rows in this table, listing schematic design recommendations, e.g. 'buildings oriented on east–west axis to reduce sun exposure', 'medium-sized openings, 20%–40% of wall area'. 6. * Design Development Recommendations. Again the yearly totals from table 4 are used to read off recommendations, e.g. 'roofs should be high-mass and well insulated'.
xsd:nonNegativeInteger 5231

data from the linked data cloud