Fourier-transform ion cyclotron resonance
http://dbpedia.org/resource/Fourier-transform_ion_cyclotron_resonance
Die FT-ICR-Massenspektrometrie (FT-ICR-MS = Fourier-Transform Ionenzyklotronresonanz Massenspektrometrie) ist ein Verfahren der Ionenfallen-Massenspektrometrie mit sehr hoher Massenauflösung.
rdf:langString
In spettrometria di massa l'analizzatore a risonanza ionica ciclotronica a trasformata di Fourier è un analizzatore basato sul fatto che uno ione eccitato con radiofrequenze emette energia. Richiede un vuoto spinto, dell'ordine di 10-9-10-10 Torr. È un analizzatore non distruttivo, ha risoluzione fino a 1.000.000. Si indica comunemente come FT-ICR, acronimo dell'inglese Fourier transform-ion cyclotron resonance.
rdf:langString
フーリエ変換イオンサイクロトロン共鳴質量分析計(Fourier Transfom Ion Cyclotron Resonance Mass Spectrometer;FT-ICR-MS)とは、質量分析計の形式の一つ。
rdf:langString
Масс-анализатор ионно-циклотронного резонанса с Фурье-преобразованием (Fourier transfrom ion cyclotron resonance - FT/ICR MS, Fourier transform mass spectrometry) - тип масс-анализатора для определения отношения массы к заряду по циклотронной частоте иона в фиксированном магнитном поле.
rdf:langString
Fourier-transform ion cyclotron resonance mass spectrometry is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (m/z) of ions based on the cyclotron frequency of the ions in a fixed magnetic field. The ions are trapped in a Penning trap (a magnetic field with electric trapping plates), where they are excited (at their resonant cyclotron frequencies) to a larger cyclotron radius by an oscillating electric field orthogonal to the magnetic field. After the excitation field is removed, the ions are rotating at their cyclotron frequency in phase (as a "packet" of ions). These ions induce a charge (detected as an image current) on a pair of electrodes as the packets of ions pass close to them. The resulting signal is called a free induction decay (FID), tra
rdf:langString
La espectrometría de masas por resonancia de ciclotrón iónica por transformada de Fourier (FT-ICR por sus siglas en inglés) es un tipo de analizador de masas (o espectrómetro de masas) para determinar la relación masa-carga (m/z) de iones en función de la frecuencia de ciclotrón de los iones en un campo magnético fijo. Los iones están atrapados en una trampa Penning (un campo magnético con placas de captura eléctricas), donde son excitados (en sus frecuencias de ciclotrón resonantes) a un radio de ciclotrón más grande por un campo eléctrico oscilante ortogonal al campo magnético. Después de que se elimina el campo de excitación, los iones giran en su frecuencia de ciclotrón en fase (como un "paquete" de iones). Estos iones inducen una carga (detectada como una corriente de imagen) en un p
rdf:langString
La spectrométrie de masse à résonance cyclotronique ionique (FT-ICR-MS) est un instrument possédant un haut pouvoir de résolution et une bonne exactitude sur la masse très important pour l’analyse des protéines. C’est une technique basée sur le piégeage et l’excitation des ions dans une cellule ICR (résonance cyclotronique des ions) sous l’action d’un champ électromagnétique. Le spectre de masse est obtenu via la transformée de Fourier qui convertit le signal temporel acquis en spectre de fréquence proportionnel à la masse. FT-ICR-MS a été développée pour la première fois par Comisarow et Marshall en 1974, et l’utilisation du principe d’ICR dans un spectre de masse par Sommer. Cette technique d’analyse est très appliquée dans le domaine pharmaceutique, biologique par exemple pour l’identif
rdf:langString
Analizator cyklotronowego rezonansu jonów z fourierowską transformacją wyników (Fourier Transform Ion Cyclotron Resonance, FT-ICR) – analizator stosunku masy do ładunku elektrycznego jonów, jest głównym elementem konstrukcji niektórych spektrometrów mas. W pułapce analizatora poprzez odpowiednie wzbudzanie można selekcjonować jony, usuwać wybrane jony, chłodzić jony.
rdf:langString
傅里叶变换离子回旋共振质谱法也称作傅里叶变换质谱分析,这是一种根据给定磁场中的离子回旋频率来测量离子(m/z)的质谱分析方法。彭宁离子阱(Penning Trap)中的离子被垂直于磁场的震荡电场激发出一个更大的回旋半径,这种激发作用同时也会导致离子的同相移动(形成离子束)。当回旋的离子束接近一对捕集板时,捕集板上会检测到影像电流信号。这种信号被称为自由感应衰减(FID),是一种由许多重叠的正弦波组成的瞬态或干涉图。通过傅里叶变换,我们可以从这些信号数据中萃取出有用的信号形成质谱。 傅里叶变换离子回旋共振质谱法(FTICR-MS)具有非常高的析像能力,可以十分精确地测定物质。因此对于FTICR-MS的使用主要是利用它的高分辨率检测分子组成。这一检测的理论前提是元素在这一过程中会发生质量亏损。此外,FTICR-MS通常也被用来研究复杂的混合物。这是由于它所产生的分析图像具有较窄的峰宽,能够将两个质量相近的离子返回的信号(质荷比m/z)区分开来。 利用电喷射离子化作用产生的大量电荷,这种高分辨率同样也可以应用于蛋白质等高分子研究中。这些大分子中包含的同位素分布能够产生一系列同位素峰,由于这些同位素峰在质荷比坐标轴上十分接近,因此我们就要用到FTICR所具有的高解析分辨能力,结合大量电荷喷射来对其进行观察研究。
rdf:langString
rdf:langString
FT-ICR-Massenspektrometrie
rdf:langString
Espectrometría de resonancia ciclotrónica por transformada de Fourier
rdf:langString
Fourier-transform ion cyclotron resonance
rdf:langString
Analizzatore a risonanza ionica ciclotronica a trasformata di Fourier
rdf:langString
Spectrométrie de masse à résonance cyclonique ionique
rdf:langString
フーリエ変換イオンサイクロトロン共鳴質量分析計
rdf:langString
Analizator cyklotronowego rezonansu jonów z fourierowską transformacją wyników
rdf:langString
Масс-анализатор ионно-циклотронного резонанса с Фурье-преобразованием
rdf:langString
傅里叶变换离子回旋共振质谱法
rdf:langString
Fourier transform ion cyclotron resonance
xsd:integer
2182716
xsd:integer
1070313346
rdf:langString
A FTMS instrument at the Pacific Northwest National Laboratory, USA
rdf:langString
Die FT-ICR-Massenspektrometrie (FT-ICR-MS = Fourier-Transform Ionenzyklotronresonanz Massenspektrometrie) ist ein Verfahren der Ionenfallen-Massenspektrometrie mit sehr hoher Massenauflösung.
rdf:langString
Fourier-transform ion cyclotron resonance mass spectrometry is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (m/z) of ions based on the cyclotron frequency of the ions in a fixed magnetic field. The ions are trapped in a Penning trap (a magnetic field with electric trapping plates), where they are excited (at their resonant cyclotron frequencies) to a larger cyclotron radius by an oscillating electric field orthogonal to the magnetic field. After the excitation field is removed, the ions are rotating at their cyclotron frequency in phase (as a "packet" of ions). These ions induce a charge (detected as an image current) on a pair of electrodes as the packets of ions pass close to them. The resulting signal is called a free induction decay (FID), transient or interferogram that consists of a superposition of sine waves. The useful signal is extracted from this data by performing a Fourier transform to give a mass spectrum.
rdf:langString
La espectrometría de masas por resonancia de ciclotrón iónica por transformada de Fourier (FT-ICR por sus siglas en inglés) es un tipo de analizador de masas (o espectrómetro de masas) para determinar la relación masa-carga (m/z) de iones en función de la frecuencia de ciclotrón de los iones en un campo magnético fijo. Los iones están atrapados en una trampa Penning (un campo magnético con placas de captura eléctricas), donde son excitados (en sus frecuencias de ciclotrón resonantes) a un radio de ciclotrón más grande por un campo eléctrico oscilante ortogonal al campo magnético. Después de que se elimina el campo de excitación, los iones giran en su frecuencia de ciclotrón en fase (como un "paquete" de iones). Estos iones inducen una carga (detectada como una corriente de imagen) en un par de electrodos a medida que los paquetes de iones pasan cerca de ellos. La señal resultante se llama (FID), transitoria o interferograma que consiste en una superposición de ondas sinusoidales. La señal útil se extrae de estos datos realizando una transformación de Fourier para dar un espectro de masas.
rdf:langString
La spectrométrie de masse à résonance cyclotronique ionique (FT-ICR-MS) est un instrument possédant un haut pouvoir de résolution et une bonne exactitude sur la masse très important pour l’analyse des protéines. C’est une technique basée sur le piégeage et l’excitation des ions dans une cellule ICR (résonance cyclotronique des ions) sous l’action d’un champ électromagnétique. Le spectre de masse est obtenu via la transformée de Fourier qui convertit le signal temporel acquis en spectre de fréquence proportionnel à la masse. FT-ICR-MS a été développée pour la première fois par Comisarow et Marshall en 1974, et l’utilisation du principe d’ICR dans un spectre de masse par Sommer. Cette technique d’analyse est très appliquée dans le domaine pharmaceutique, biologique par exemple pour l’identification des protéines.
rdf:langString
In spettrometria di massa l'analizzatore a risonanza ionica ciclotronica a trasformata di Fourier è un analizzatore basato sul fatto che uno ione eccitato con radiofrequenze emette energia. Richiede un vuoto spinto, dell'ordine di 10-9-10-10 Torr. È un analizzatore non distruttivo, ha risoluzione fino a 1.000.000. Si indica comunemente come FT-ICR, acronimo dell'inglese Fourier transform-ion cyclotron resonance.
rdf:langString
フーリエ変換イオンサイクロトロン共鳴質量分析計(Fourier Transfom Ion Cyclotron Resonance Mass Spectrometer;FT-ICR-MS)とは、質量分析計の形式の一つ。
rdf:langString
Analizator cyklotronowego rezonansu jonów z fourierowską transformacją wyników (Fourier Transform Ion Cyclotron Resonance, FT-ICR) – analizator stosunku masy do ładunku elektrycznego jonów, jest głównym elementem konstrukcji niektórych spektrometrów mas. Analizator zbudowany jest w oparciu o pułapkę jonową. Jony wstrzyknięte do pułapki poruszają się w polu magnetycznym. W pierwszej fazie jony są wzbudzone (przyspieszane) zmiennym polem elektrycznym, wzbudzeniu ulegają tylko jony będące w rezonansie cyklotronowym z pobudzającym je polem. Po wzbudzeniu jony krążą w polu magnetycznym jako „pakiet” jonów. Krążący pakiet jonów indukuje napięcie elektryczne w elektrodach detekcyjnych. Indukowany sygnał rejestruje się, jako zależność napięcia od czasu. Poprzez wykonanie transformacji Fouriera zależność napięcia od czasu jest przekształcana na rozkład ilości jonów od stosunku masy do ładunku. Pomiar nie usuwa (zazwyczaj) badanych jonów z pułapki. W pułapce analizatora poprzez odpowiednie wzbudzanie można selekcjonować jony, usuwać wybrane jony, chłodzić jony. Analizatory FT-ICR są znacznie szybsze niż tradycyjne analizatory ICR. Inne parametry takie jak rozdzielczość, czułość, są podobne. Do przetwarzania sygnału z analizatora FT-ICR stosuje się komputery. Analizatory FT-ICR wyparły obecnie z rynku analizatory ICR.
rdf:langString
Масс-анализатор ионно-циклотронного резонанса с Фурье-преобразованием (Fourier transfrom ion cyclotron resonance - FT/ICR MS, Fourier transform mass spectrometry) - тип масс-анализатора для определения отношения массы к заряду по циклотронной частоте иона в фиксированном магнитном поле.
rdf:langString
傅里叶变换离子回旋共振质谱法也称作傅里叶变换质谱分析,这是一种根据给定磁场中的离子回旋频率来测量离子(m/z)的质谱分析方法。彭宁离子阱(Penning Trap)中的离子被垂直于磁场的震荡电场激发出一个更大的回旋半径,这种激发作用同时也会导致离子的同相移动(形成离子束)。当回旋的离子束接近一对捕集板时,捕集板上会检测到影像电流信号。这种信号被称为自由感应衰减(FID),是一种由许多重叠的正弦波组成的瞬态或干涉图。通过傅里叶变换,我们可以从这些信号数据中萃取出有用的信号形成质谱。 傅里叶变换离子回旋共振质谱法(FTICR-MS)具有非常高的析像能力,可以十分精确地测定物质。因此对于FTICR-MS的使用主要是利用它的高分辨率检测分子组成。这一检测的理论前提是元素在这一过程中会发生质量亏损。此外,FTICR-MS通常也被用来研究复杂的混合物。这是由于它所产生的分析图像具有较窄的峰宽,能够将两个质量相近的离子返回的信号(质荷比m/z)区分开来。 利用电喷射离子化作用产生的大量电荷,这种高分辨率同样也可以应用于蛋白质等高分子研究中。这些大分子中包含的同位素分布能够产生一系列同位素峰,由于这些同位素峰在质荷比坐标轴上十分接近,因此我们就要用到FTICR所具有的高解析分辨能力,结合大量电荷喷射来对其进行观察研究。 FTICR-MS与其他质谱分析仪器最大的不同点在于,它不是用离子去撞击一个类似电子倍增器的感应装置,只是让离子从感应板附近经过。而且对于物质的测定也不像其他技术手段一样利用时空法,而是根据频率来进行测量。利用象限仪(sector instruments)检测时,不同的离子会在不同的地方被检测出来;利用飞行时间法(time-of-flight)检测时,不同的离子会在不同的时间被检测出来;而利用FTICR-MS检测时,离子会在给定的时空条件下被同时检测出来。 FTICR是由英属哥伦比亚大学(University of British Columbia)的Alan G. Marshall 和 Melvin B. Comisarow二位学者发明的。首篇相关论文发表于1974年的《化学物理学》杂志。这一发明的灵感来源于传统的离子回旋共振(ICR)和傅里叶核磁共振(FT-NMR)波谱学。Alan G. Marshall随后在俄亥俄州立大学、佛罗里达州立大学继续丰富和发展了这项技术。
rdf:langString
FTICR
xsd:nonNegativeInteger
17557