Dual loop
http://dbpedia.org/resource/Dual_loop an entity of type: Software
الحلقة (الدورة) المزدوجة هي طريقة لفصل الدائرة الكهربية وتستخدم في تطبيقات الحماية الإكترونية خاصة أجهزة الإنذار الدخيلة الحديثة.
* تسمى بالحلقة المزدوجة لاحتوائها على دائرتين (الإنذار ومكافح التلاعب) ويتم دمجهما داخل دائرة واحدة تستخدم المقاومات .
* لقد انتشر استخدامها انتشارًا واسعًا في السنوات القليلة الماضية واستبدلت بأنظمة الدوائر المغلقة الأساسية بسبب تغير الممارسات والمعايير العالمية .
rdf:langString
Dual-loop is a method of electrical circuit termination used in electronic security applications, particularly modern intruder alarms. It is called 'dual-loop' because two circuits (alarm and anti-tamper) are combined into one using resistors. Its use became widespread in the early 21st century, replacing the basic closed-circuit system, mainly because of changes in international standards and practices.
rdf:langString
rdf:langString
الحلقة المزدوجة
rdf:langString
Dual loop
xsd:integer
14790437
xsd:integer
1019829961
rdf:langString
الحلقة (الدورة) المزدوجة هي طريقة لفصل الدائرة الكهربية وتستخدم في تطبيقات الحماية الإكترونية خاصة أجهزة الإنذار الدخيلة الحديثة.
* تسمى بالحلقة المزدوجة لاحتوائها على دائرتين (الإنذار ومكافح التلاعب) ويتم دمجهما داخل دائرة واحدة تستخدم المقاومات .
* لقد انتشر استخدامها انتشارًا واسعًا في السنوات القليلة الماضية واستبدلت بأنظمة الدوائر المغلقة الأساسية بسبب تغير الممارسات والمعايير العالمية .
rdf:langString
Dual-loop is a method of electrical circuit termination used in electronic security applications, particularly modern intruder alarms. It is called 'dual-loop' because two circuits (alarm and anti-tamper) are combined into one using resistors. Its use became widespread in the early 21st century, replacing the basic closed-circuit system, mainly because of changes in international standards and practices. Dual-loop allows the burglar alarm control panel to read the values of end-of-line resistors for the purpose of telling a zone's status. For example: if an alarm system's software uses 2K ohms as its non-alarm value, an inactive detector will give a reading of 2K ohms as the circuit is passing through just one resistor. When the detector goes into an active state (i.e. a door contact being opened), the circuit path has been altered and it must now pass through a second resistor wired in series with the first. This gives a reading of 4K ohms and will trigger an intruder alarm. If a resistance reading is not recognised by the system either due to short-circuit or open-circuit, an anti-tamper alarm will trigger. Dual loop is more commonly known as Balanced EOL (End of Line) resistors. It is more secure than the former Double Pole loop, but nevertheless can be bypassed by someone with sufficient knowledge of security alarm systems.
xsd:nonNegativeInteger
1884