Auxiliary electrode
http://dbpedia.org/resource/Auxiliary_electrode an entity of type: Artifact100021939
القطب المساعد، و هو قطب كهربائي يستخدم في خلية كهروكيميائية ثلاثية الأقطاب لتحليل الفولتامتري أو التفاعلات الكهروكيميائية الأخرى التي من المتوقع أن يتدفق فيها تيار كهربائي. يختلف القطب المساعد عن القطب المرجعي، والذي يقوم بقياس الجهود الكهربائية، والقطب الكهربي العامل الذي تحدث على سطحه التفاعلات.
rdf:langString
The auxiliary electrode, often also called the counter electrode, is an electrode used in a three electrode electrochemical cell for voltammetric analysis or other reactions in which an electric current is expected to flow. The auxiliary electrode is distinct from the reference electrode, which establishes the electrical potential against which other potentials may be measured, and the working electrode, at which the cell reaction takes place. Auxiliary electrodes are often fabricated from electrochemically inert materials such as gold, platinum, or carbon.
rdf:langString
Une électrode auxiliaire est une électrode utilisée dans une cellule électrochimique à trois électrodes pour l'analyse voltamétrique ou d'autres réactions dans lesquelles un courant électrique est attendu. Les électrodes auxiliaires sont souvent fabriquées à partir de matériaux électrochimiquement inertes tels que l'or, le platine ou le carbone.
rdf:langString
L'elettrodo ausiliario, spesso chiamato anche controelettrodo, è un elettrodo utilizzato in una cella elettrochimica a tre elettrodi per l'analisi voltammetrica o per altre reazioni in cui deve fluire una corrente elettrica. Il potenziale dell'elettrodo ausiliario è di segno opposto a quello dell'elettrodo di lavoro, ma la sua corrente e il suo potenziale non vengono misurati. Gli elettrodi ausiliari sono spesso fabbricati utilizzando materiali elettrochimicamente inerti come oro, platino o carbonio.
rdf:langString
rdf:langString
Auxiliary electrode
rdf:langString
قطب مساعد
rdf:langString
Elèctrode auxiliar
rdf:langString
Électrode auxiliaire
rdf:langString
Elettrodo ausiliario
xsd:integer
14171783
xsd:integer
1099084710
rdf:langString
Auxiliary electrode
rdf:langString
القطب المساعد، و هو قطب كهربائي يستخدم في خلية كهروكيميائية ثلاثية الأقطاب لتحليل الفولتامتري أو التفاعلات الكهروكيميائية الأخرى التي من المتوقع أن يتدفق فيها تيار كهربائي. يختلف القطب المساعد عن القطب المرجعي، والذي يقوم بقياس الجهود الكهربائية، والقطب الكهربي العامل الذي تحدث على سطحه التفاعلات. في ، يتم تطبيق تيار أو جهد معروف بين قطب العمل و القطب المساعد و خلال هذه العملية يمكن قياس المتغيرات الآخرى. يعمل القطب المساعد كقطب سالب عندما يعمل القطب العامل كقطب موجب والعكس صحيح. غالبًا ما يكون القطب المساعد ذو مساحة سطح أكبر بكثير (يجب أن يكون سطح قطب المساعد أكبر بعشر مرات على الأقل ) من مساحة قطب العمل لضمان أن نصف التفاعل الذي يحدث في القطب المساعد يمكن أن يحدث بسرعة كافية حتى لا يحد من العملية على سطح قطب العمل. و يعد وضع قطب العداد مقابل القطب العامل مهمًا جدًا عند استخدام خلية من ثلاثة قطب كهربائي لإجراء التحاليل الكهروكيميائية ، يوفر القطب المساعد، جنبًا إلى جنب مع القطب العامل، دائرة كهربائية يتم فيها تطبيق التيار كهربائي أو قياسه. هنا ، لا يتم قياس جهد القطب المساعد عادةً ويتم تعديله لموازنة التفاعل الذي يحدث في قطب العمل. تسمح هذه الدائرة بقياس جهد قطب العمل مقابل قطب مرجعي معروف دون المساس باستقرار هذا القطب المرجعي عن طريق تمرير التيار أعلى منه.يمكن عزل القطب المساعد عن قطب العمل باستخدام مزيج تزجيج. حيث يمنع هذا العزل أي منتجات ثانوية متولدة على القطب المساعد من تلويث المحلول المدروس: على سبيل المثال ، إذا تم إجراء اختزال على سطح قطب العمل في محلول مائي، فقد ينطلق الأكسجين من القطب المساعد. هذا العزل أمر بالغ الأهمية أثناء التحليل الكهروكيميائي للمركبات التي لها تفاعلات أكسدة واختزال عكوسة. غالبًا ما تُصنع الأقطاب الكهربائية المساعدة من مواد خاملة كهروكيميائيًا مثل الذهب أو البلاتين أو الكربون. و يجب أن يكون قطب المساعد موصلًا كهربائيًا جيدًا. هذا الشرط واضح. إذا لم يكن القطب المساعد موصلًا جيدًا ، فهذا يعني أن كمية ضعيفة من التيار يمكن أن تمر عبر سطح القطب المساعد، والذي سيحدد لنا بعد ذلك التيار المقاس للخلية الكهروكيميائية. لذلك ، سيوفر التيار المقاس معلومات حول خصائص القطب المساعد بدل نصف التفاعل الذي يحدث على سطح قطب العمل.
rdf:langString
The auxiliary electrode, often also called the counter electrode, is an electrode used in a three electrode electrochemical cell for voltammetric analysis or other reactions in which an electric current is expected to flow. The auxiliary electrode is distinct from the reference electrode, which establishes the electrical potential against which other potentials may be measured, and the working electrode, at which the cell reaction takes place. In a two-electrode system, either a known current or potential is applied between the working and auxiliary electrodes and the other variable may be measured. The auxiliary electrode functions as a cathode whenever the working electrode is operating as an anode and vice versa. The auxiliary electrode often has a surface area much larger than that of the working electrode to ensure that the half-reaction occurring at the auxiliary electrode can occur fast enough so as not to limit the process at the working electrode. When a three electrode cell is used to perform electroanalytical chemistry, the auxiliary electrode, along with the working electrode, provides a circuit over which current is either applied or measured. Here, the potential of the auxiliary electrode is usually not measured and is adjusted so as to balance the reaction occurring at the working electrode. This configuration allows the potential of the working electrode to be measured against a known reference electrode without compromising the stability of that reference electrode by passing current over it. The auxiliary electrode may be isolated from the working electrode using a glass frit. Such isolation prevents any byproducts generated at the auxiliary electrode from contaminating the main test solution: for example, if a reduction is being performed at the working electrode in aqueous solution, oxygen may be evolved from the auxiliary electrode. Such isolation is crucial during the bulk electrolysis of a species which exhibits reversible redox behavior. Auxiliary electrodes are often fabricated from electrochemically inert materials such as gold, platinum, or carbon.
rdf:langString
Une électrode auxiliaire est une électrode utilisée dans une cellule électrochimique à trois électrodes pour l'analyse voltamétrique ou d'autres réactions dans lesquelles un courant électrique est attendu. Les cellules à trois électrodes comprennent (1) une électrode de travail à la surface de laquelle la réaction électrochimique a lieu, (2) une électrode de référence qui établit le potentiel électrique contre lequel d'autres potentiels peuvent être mesurés, et (3) l'électrode auxiliaire qui sert simplement à transporter le courant traversant la cellule et à la surface de laquelle aucun processus intéressant ne se produit. L'électrode auxiliaire fournit un circuit sur lequel du courant est appliqué ou mesuré. Le potentiel de l'électrode auxiliaire n'est généralement pas mesuré et est ajusté de manière à équilibrer la réaction se produisant au niveau de l'électrode de travail. Cette configuration permet de mesurer le potentiel de l'électrode de travail par rapport à l'électrode de référence connue sans compromettre la stabilité de cette électrode de référence en y faisant passer du courant. L'électrode auxiliaire peut être isolée de l'électrode de travail à l'aide d'un verre fritté. Une telle isolation évite que des sous-produits générés au niveau de l'électrode auxiliaire ne contaminent la solution de test principale. Par exemple, si une réduction est effectuée sur l'électrode de travail en solution aqueuse, du dioxygène peut être dégagé au niveau de l'électrode auxiliaire. Cette isolation est cruciale lors de l'électrolyse en masse d'une espèce présentant un comportement redox réversible. Les électrodes auxiliaires sont souvent fabriquées à partir de matériaux électrochimiquement inertes tels que l'or, le platine ou le carbone.
rdf:langString
L'elettrodo ausiliario, spesso chiamato anche controelettrodo, è un elettrodo utilizzato in una cella elettrochimica a tre elettrodi per l'analisi voltammetrica o per altre reazioni in cui deve fluire una corrente elettrica. L'elettrodo ausiliario è distinto dall'elettrodo di riferimento, il quale stabilisce il potenziale elettrico contro cui altri potenziali possono essere misurati, e dall'elettrodo di lavoro, in cui ha luogo la reazione di cella. Nell'elettrodo ausiliario non avvengono invece le reazioni elettrochimiche studiate e il suo unico scopo è quello di garantire il flusso di corrente attraverso la cella elettrochimica. Viene quindi utilizzato per assicurare che la corrente non circoli attraverso l'elettrodo di riferimento (sistema a tre elettrodi), il che influenzerebbe il potenziale dell'elettrodo di riferimento. L'elettrodo ausiliario spesso possiede un'area superficiale più grande rispetto all'elettrodo di lavoro per assicurare che le reazioni che avvengono sull'elettrodo di lavoro non siano limitate dall'area della superficie tramite l'elettrodo ausiliario. Il potenziale dell'elettrodo ausiliario è di segno opposto a quello dell'elettrodo di lavoro, ma la sua corrente e il suo potenziale non vengono misurati. Quando si utilizza una cella a tre elettrodi in ambito elettroanalitico, l'elettrodo ausiliario è spesso isolato dall'elettrodo di lavoro utilizzando vetro poroso. Tale isolamento previene la contaminazione da parte dei sottoprodotti generati all'elettrodo ausiliario riguardo al corpo della soluzione analitica oggetto di studio e l'interferenza con la misura analitica fatta dall'elettrodo di lavoro. Gli elettrodi ausiliari sono spesso fabbricati utilizzando materiali elettrochimicamente inerti come oro, platino o carbonio.
rdf:langString
A00535
xsd:nonNegativeInteger
3300